Inquiry
Form loading...
Booster Regulator Water Supply Equipment

Water Supply Booster Pump

Booster Regulator Water Supply Equipment

Booster Regulator Water Supply Equipment is booster regulate equipment,which manufactured based on national building standard design.The device consist of diaphragm pressure tank, booster pump, electric control box, instrumentation and piping accessories and other components, suitable for multi-story and high-rise building and booster requirements for fire hydrant water supply systems and automatic water spraying fire-extinguishing systems and other fire-fighting and water supply system.

  • Product Model ZW(L)
  • Nature BORRA
  • Update Time 2023-03-28
  • Visits 913

Description

Booster Regulator Water Supply Equipment is booster regulate equipment,which manufactured based on national building standard design.The device consist of diaphragm pressure tank, booster pump, electric control box, instrumentation and piping accessories and other components, suitable for multi-story and high-rise building and booster requirements for fire hydrant water supply systems and automatic water spraying fire-extinguishing systems and other fire-fighting and water supply system.

Features:
1, With pump,electric control cabinet, diaphragm type pressure tanks,pipes, four-in-one combination network, and accompanied with the isolator without pre-embedded holes, designers can easily select device model and size,by counting Parameters. Electric Designers do not need to design the control circuit, only need to design for the cable line to pumping stations and the device. Choose convenience, can greatly shorten the design cycle for designers and construction time for builder.
2, Diaphram pressure tank disposable inflatable, durable lifetime. Water vapor isolation can prevent pollution of water.
3, Small occupation area, low investment, automatic operation.
4, Equipment with dual power connector, dual power automatic (manual) switch, the device can be made according to the design requirements.
5, with automatic protection and failover capabilities. Any failure of a pump (electrical failure or hydraulic failure) can start the standby pump.
6, can be connected with the fire center (according to design).
7, can choose the tank, regulator manner based on customer needs and control functions.
8, the main electrical accessories using domestic or brand-name products, reliable and stable operation.

Equipment Construction:
regulator pump two set (depending on design requirements can be one set ),a main pump,a standby pump, a diaphragm pressure tank, a electric cabinet, a combination of instrumentation valves and a pipe network set, consisting of a diaphragm stabilization pressure water supply equipment.

Application:
1, In order to ensure that the fire pump at stand-by time, fire fighting equipment to meet the emergency fire.
2, Mainly used for fire protection water supply in petrochemical, natural gas, power plants, textile cotton, wharf, aviation, warehousing, high-rise buildings and other industries.
3, Foam fire extinguishing system can also be used for water vessels, offshore tankers and fire ships and other occasions.
4, Can be used for direct extraction of municipal pipe network for water supply fire fighting water supply occasions.
5, Can be used for life, fire a water supply equipment for the occasion.
6, Can be used for fire water supply pressure, fire inspection and other special occasions.  

Technical parameters

Type

Fire Pressure

(Mpa)

P1

Vertical Diaphragm PressureTank Pressure

Working Pressure(Mpa)

Regulators Water Volume (L)

Model specification

Working Pressure Ratio αb

Fire Storage Volume(L)

Calibration Volume

Actual Volume

ZW(L)-I-X-7

0.10

XQG800×0.6

0.60

300

319

P1=0.10 PS1=0.26 P1=0.23  PS2=0.31

54

ZW(L)-I-Z-10

0.16

XQG800×0.6

0.80

150

159

P1=0.16 PS1=0.26 P1=0.23  PS2=0.36

70

ZW(L)-I-X-10

0.16

XQG800×0.6

0.60

300

319

P1=0.16 PS1=0.36 P1=0.33  PS2=0.42

52

ZW(L)-I-X-13

0.22

XQG1000×0.6

0.76

300

329

P1=0.22 PS1=0.35 P1=0.32  PS2=0.40

97

ZW(L)-I-XZ-10

0.16

XQG1000×0.6

0.65

450

480

P1=0.16 PS1=0.33 P1=0.30  PS2=0.38

86

ZW(L)-I-XZ-13

0.22

XQG1000×0.6

0.67

450

452

P1=0.22 PS1=0.41 P1=0.38  PS2=0.46

80

ZW(L)-II-Z-

A

0.22 -0.38

XQG800×0.6

0.80

150

159

P1=0.38 PS1=0.53 P1=0.50  PS2=0.60

61

B

0.38 -0.50

XQG800×1.0

0.80

150

159

P1=0.50  PS1=0.68 P1=0.65  PS2=0.75

51

C

0.50 -0.65

XQG1000×1.0

0.85

150

206

P1=0.65 PS1=0.81 P1=0.78  PS2=0.86

59

D

0.65 -0.85

XQG1000×1.6

0.85

150

206

P1=0.85 PS1=1.04 P1=1.02  PS2=1.10

57

E

0.85 -1.0

XQG1000×1.6

0.85

150

206

P1=1.00 PS1=1.21 P1=1.19  PS2=1.27

50

ZW(L)-II-X-

A

0.22-0.38

XQG800×0.6

0.78

300

302

P1=0.38 PS1=0.53 P1=0.50  PS2=0.60

72

B

0.38-0.50

XQG800×1.0

0.78

300

302

P1=0.50 PS1=0.68 P1=0.65  PS2=0.75

61

C

0.50-0.65

XQG1000×1.0

0.78

300

302

P1=0.65 PS1=0.88 P1=0.86  PS2=0.93

51

D

0.65-0.85

XQG1200×1.6

0.85

300

355

P1=0.85 PS1=1.05 P1=1.02  PS2=1.10

82

E

0.85-1.0

XQG1200×1.6

0.85

300

355

P1=1.00 PS1=1.21 P1=1.19  PS2=1.26

73

ZW(L)-II-XZ-

A

0.22-0.38

XQG1200×0.6

0.80

450

474

P1=0.38 PS1=0.53 P1=0.50  PS2=0.60

133

B

0.38-0.50

XQG1200×1.0

0.80

450

474

P1=0.50 PS1=0.68 P1=0.65  PS2=0.75

110

C

0.50-0.65

XQG1200×1.0

0.80

450

474

P1=0.65 PS1=0.81 P1=0.78  PS2=0.86

90

D

0.65-0.85

XQG1200×1.6

0.80

450

474

P1=0.85 PS1=1.04 P1=1.02  PS2=1.10

73

E

0.85-1.0

XQG1200×1.6

0.80

450

474

P1=1.00 PS1=1.21 P1=1.19  PS2=1.27

64